Inverter Frequency Tachometer Line Speed Meter 0-10V Display 0-4-20mA Meter 9999RPM Digital RPM Meter for Motor

Line Speed Meter
$61.14
Quantity
Contact us

Get in touch

Please email us at sale1@rfid-life.com with a detailed overview of your project requirement. So that we can offer you the fastest and best support. You may expect a reply within 24 business hours. – Welcomes Your Comments And Questions.


Sales Department

Phone: +86 18205991243
Whatsapp: +86 18205991243
Telegram: +86 18205991243
Email: sale1@rfid-life.com
Address: No.987,High-Tech Park,Huli District,Xiamen,China


Support Department

Email: support@rfid-life.com


Business Hours

Monday - Friday 9am to 6pm

Saturday - 9am to 12am

Sunday - Closed

Description
Inverter Frequency Tachometer Line Speed Meter 0-10V Display 0-4-20mA Meter 9999RPM Digital RPM Meter for Motor
Product Description

Note

We have following style can choose, please leave us a note which one do you want. Otherwise we sent at random.
DC0-10V/0-9999r/min 96*48mm DC4-20mA/0-9999r/min 96*48mm DC0-20mA/0-9999 r/min 96*48mm DC0-10V/0-9999m/min 96*48mm DC0-20mA/0-9999 m/min 96*48mm DC4-20mA/0-9999m/min 96*48mm Upper and lower limit alarm output Analog output RS485 communication Power supply DC24V Power supply AC85-265V/DC100-300V 120*120mm 96*96mm 80*80mm 72*72mm 96*48mm 48*48mm
Specification
Measurement accuracy
value
Current
0.5 level
Signal input
Guangdong
Wiring
Simplex
Rated current
AC1A. AC5A, DC 20mA, DC 1A, DC 5A, DC 75mV
Overload
1. 2 times (continuous), 10 times/5 seconds (instantaneous)
Power consumption
<0.4VA/phase
Impedance
<20mΩ
Frequency
45~65Hz or DC
Auxiliary power
The scope of work
AC/DC 80V~270V. AC220V. AC380V. AC100V. DC48V. DC24V
Power consumption
<4VA
Functional module
Communication Interface
1 channel RS-485 communication, Modbus-RTU protocol
Baud rate: 1200~9600bps, default 2400 bps
Switch input
Support 2 dry node input
Switch output
Support 2 relay outputs, capacity: AC 250V/5A, DC 30V5A
Transmission output
Support 1 analog output: 0/4~20mA or 0~5/10V
Surroundings
Operating temperature
-10°C~+55°C
Storage temperature
-25°C~+70°C
Relative humidity
≤93%, no corrosive gas place
Altitude
≤2500m
Safety
Insulation resistance
>100MΩ
AC withstand voltage
AC 2KV
EMC performance
Electrostatic discharge
level 4
Electrical fast transient burst
level 4
Electrical fast transient burst
level 4
Dimensions
Frame size (mm)
120x120; 80x80; 96x48; 96x96; 80x80; 48x48; 120x60; 160x80
Hole size (mm)
111x111; 76x76; 92x45; 92x92; 68*68; 45x45; 114x56; 152x76
Installation Instructions

Keyboard keys:

"SET": Menu editing or right shift of numerical value (in digital input state); <—Move up or increase the value of the menu item; —>Move down or decrease the value of the menu item; <—|Back to the upper menu, back and save the settings during parameter setting.

Note

1. In the input state of CT value and PT value, the "SET" key is the key to move the cursor to the right. AC current CT value: CT = primary current value of current transformer/secondary current value of current transformer DC current CT value: CT=shunt primary current value/5 (signal input DC75mV) CT=display value/1 (signal input DC 20mA, DC 4-20mA) AC voltage PT value: PT=Primary voltage value of voltage transformer/Secondary voltage value of voltage transformer DC voltage PT value: PT=display value/input value 2. Indicator light: "K": thousand units, the real value is one-thousand times the displayed value.
3. Display character description:
SET
Set up
CT
Current ratio
0001-9999
PT
Voltage transformation ratio
0001-9999
Details Images