(function(){
let w = window.innerWidth;
function setHeaderCssVar() {
const headerEle = document.getElementById('shoplaza-section-header');
if(!headerEle){ return };
document.body.style.setProperty('--window-height', `${window.innerHeight}px`);
document.body.style.setProperty('--header-height', `${headerEle.clientHeight}px`);
const mdScorllHideEle = headerEle.querySelector('.header__mobile .header__scroll_hide');
if (mdScorllHideEle) {
document.body.style.setProperty('--header-scroll-hide-height-md', `${mdScorllHideEle.clientHeight}px`);
}
const pcScorllHideEle = headerEle.querySelector('.header__desktop .header__scroll_hide');
if (pcScorllHideEle) {
document.body.style.setProperty('--header-scroll-hide-height-pc', `${pcScorllHideEle.clientHeight}px`);
}
}
function handlResize() {
if(w == window.innerWidth){return};
w = window.innerWidth;
setHeaderCssVar();
};
function init(){
setHeaderCssVar();
window.removeEventListener('resize', window._theme_header_listener)
window._theme_header_listener = handlResize;
window.addEventListener('resize', window._theme_header_listener);
}
init();
})();
${data.index + 1}/6
Description
Double Button Electronic Switch Bistable Relay 12v Module One On One Off Bistable Two Button Switch Power-off Reset
Product Description
Module function description: 1. Connect to the power supply, do not press any buttons, the module will not work; 2. Press the'open' button, the module will start output, and the relay will be closed; 3. Press--the ‘off’ button, the module stops output and the relay is released.
Specification
item
value
Module name
Double button electronic switch module
Working voltage
DC5V \ DC12V \ DC24V
Working current
5V-35mA \ 12V-30mA \ 24V-25mA
Appearance size
45*49*20mm (length x width x height)
Installation Instructions
Pin description
[1] Power positive input [2] Power negative input [3] Onboard "on" button, click the module to start output [4]'Open' extended button interface, external button\travel switch\photoelectric switch, high level trigger [5]'Off' extended button interface, external button\travel switch\photoelectric switch, high level trigger [6] On-board'off' button, click the module to turn off the output [7] The jumper is shorted to JP1, the common pin of the relay and the power input pin are connected (1 and 10 are connected) Jumper cap disconnect JP1, relay common pin is not energized (default setting) [8] Working status indicator, press--down the'open' button to light up (relay 10-9 closed, 11 -10 open, 13-12 output); Press the ‘off’ button and the light goes out (relay 10-9 is off, 11-10 is on, and 13-12 is off). [9] Relay normally open pin [10] Relay common pin [11] Relay normally closed foot [12] Output positive, output voltage value and input voltage 1 pin--like [13] The output is negative, the 2 pin and 13 pin modules have been connected, and both are negative (grounded)