Specification : Fanless Version
Quantity
Contact us

Get in touch

Please email us at sale1@rfid-life.com with a detailed overview of your project requirement. So that we can offer you the fastest and best support. You may expect a reply within 24 business hours. – Welcomes Your Comments And Questions.


Sales Department

Phone: +86 18205991243
Whatsapp: +86 18205991243
Telegram: +86 18205991243
Email: sale1@rfid-life.com
Address: No.987,High-Tech Park,Huli District,Xiamen,China


Support Department

Email: support@rfid-life.com


Business Hours

Monday - Friday 9am to 6pm

Saturday - 9am to 12am

Sunday - Closed

Description
Product Description
Product highlights:

 

1.1. Long handle potentiometer regulates voltage and current.It can be operated by hand without using a word knife.

 

1.2. With large volume radiator fin and shell.Optional fan.

 

1.3. LCD input voltage, output voltage,temperature, output current and output power;

 

1.4. Hardware protection: the input end is protected against backconnection, which will not burn out;The output end is anti-reverse irrigation, and it is unnecessary to add anti-reverse irrigation diode when charging the battery.

 

Software protection: over current protection, over power protection, over temperature protection.

 

1.5. Can be step-up and step-down, the output voltage 0.5-30V arbitrary regulation, limiting the current 0-6A arbitrary regulation;

 

1.6. Button control output ON / OFF status, and you can set the power-on default is ON or OFF;

 

1.7. Output ripple small, LC filter;

 

2. Product parameters:

 

Input voltage: 5.5-30V (input voltage 5V, you can normally achieve buck-boost, but the voltage and current meter values are not accurate; less than 4.7V, undervoltage protection)

 

Output voltage: 0.5-30V

 

Output current: Output current: the fanless version can work stably in 4A for a long time, and the fan version can reach 6A

 

Output power: Fanless version 35W, fan version 60W

 

Voltage display resolution: 0.01V, accuracy error 1%

 

Current display resolution: 0.001A, accuracy error 1%

 

Conversion efficiency: about 88%

 

Soft-start: Yes (very powerful with load startup, startup may fail)

 

Input reverse protection: Yes

 

Output anti-intrusion: Yes

 

Short circuit protection: yes

 

Temperature protection: 100  degree centigrade

 

Power protection: 60W

 

Over-current protection: 6A

 

Operating frequency: 180KHZ

 

Fan rotation conditions: current greater than 3A, or power greater than 20 watts, or temperature greater than 40   degree centigrade

 

Size: fanless version length * width * height 72*59*32mm

 

fan version    length * width * height 72*59*43mm

 

Mounting hole: diameter 3mm

 

Weight:  fan version     107g

 

3. Function Description:

 

3.1. Module has IN / OUT, ON / OFF two buttons: IN / OUT button to switch the input voltage and output voltage display, long press to switch the output current output power display; ON / OFF button control output ON or OFF, long press Set power on default output status is ON or OFF.

 

3.2.CC is the current setting potentiometer, clockwise rotation, can increase the set current, when the load current reaches the set current, enter the constant current state, CC constant current indicator (red) lights up; the right CV is the voltage setting Potentiometer, clockwise rotation, can increase the output voltage. ON indicator is the output status indicator, when the output voltage is on, otherwise off.

 

4. How to use:

 

4.1. Used as an ordinary buck-boost module with over-current protection capability

 

(1) Adjust the CV constant voltage potentiometer so that the output voltage reaches the voltage you want.

 

(2) Directly connect the output end with a short line (can directly short the output end!).Adjust CC constant current potentiometer so that the output current reaches the predetermined overcurrent protection value.(for example, the current value displayed by the module is 2A, so the maximum current can only reach 2A when you use the module, and the red constant voltage and current indicator is on when the current reaches 2A, otherwise the indicator is off)

 

Caution: When using in this state, there will be a voltage drop of 0 ~ 0.2V due to the current sampling resistor at the output. At the same time, the input and output leads will have a certain linear voltage drop This is a normal phenomenon!

 

4.2. Used as a battery charger

 

Without constant current function of the module can not be used to charge the battery, due to the power of the battery and the charger pressure drop is large, resulting in charging current is too large, causing damage to the battery, so the beginning of the battery to use constant Flow charging, when the charge to a certain extent automatically switch back to constant voltage 

 

charging.

 

(1) Determine the float voltage and charging current for which you need the rechargeable battery (if the lithium battery parameter is 3.7V / 2200mAh then the float voltage is 4.2V and the maximum charging current is 1C, ie 2200mA)

 

(2) Under no-load condition, the multimeter measures the output voltage and adjusts the constant voltage potentiometer so that the output voltage reaches the float voltage. (If the 3.7V lithium battery is charged, adjust the output voltage to 4.2V)

 

(3) Measure the output short-circuit current with 10A current meter (directly connect the two test leads to the output terminal), and adjust the constant current potentiometer so that the output current reaches the predetermined charge current value;

 

(4) Connect the battery, charging.

 

(Steps 1, 2 and 3 are as follows: input termination power supply, the output is not connected to the battery load)

 

4.3. Used as LED constant current driver module

 

(1) Make sure you need to drive the LED operating current and the maximum operating voltage;

 

(2) Under no-load conditions, the multimeter measures the output voltage and adjusts the constant voltage potentiometer so that the output voltage reaches the maximum operating voltage of the LED.

 

(3) directly connect the output with a short line (can directly short the output end!)., adjust the constant current potentiometer to make the output current reach the predetermined LED working current;

 

(4) connected to the LED, test machine.

 

(Steps 1, 2, and 3 are as follows: Input the power and output the no-load LED.)

 

Note: This module is more than 3A, 35W use, please strengthen the heat! ! !

5. Assembly Schematic
6. Note:

 

6.1. Module input IN- Prohibit short circuit with output OUT-, otherwise constant current function will be invalid.

 

6.2. Please make sure that the power of the power supply is greater than the power required by the output load!

 

6.3. If the module is to be fully loaded with output, the input voltage should be over 8V. When the input voltage is 5V, the output power is about 15W, and the voltage ammeter fails. Module current value 4A, the premise subject to the maximum output power, such as the output 17V, the current should not exceed 2A.

 

6.4. Module with output short-circuit protection, short-circuit protection module automatically shut down the output, the module can be restored on the power, if your power supply without output current limiting protection, it is recommended that the module input front-end fuse in series to increase the safety factor.