(function(){
let w = window.innerWidth;
function setHeaderCssVar() {
const headerEle = document.getElementById('shoplaza-section-header');
if(!headerEle){ return };
document.body.style.setProperty('--window-height', `${window.innerHeight}px`);
document.body.style.setProperty('--header-height', `${headerEle.clientHeight}px`);
const mdScorllHideEle = headerEle.querySelector('.header__mobile .header__scroll_hide');
if (mdScorllHideEle) {
document.body.style.setProperty('--header-scroll-hide-height-md', `${mdScorllHideEle.clientHeight}px`);
}
const pcScorllHideEle = headerEle.querySelector('.header__desktop .header__scroll_hide');
if (pcScorllHideEle) {
document.body.style.setProperty('--header-scroll-hide-height-pc', `${pcScorllHideEle.clientHeight}px`);
}
}
function handlResize() {
if(w == window.innerWidth){return};
w = window.innerWidth;
setHeaderCssVar();
};
function init(){
setHeaderCssVar();
window.removeEventListener('resize', window._theme_header_listener)
window._theme_header_listener = handlResize;
window.addEventListener('resize', window._theme_header_listener);
}
init();
})();
${data.index + 1}/4
Description
Product Description
D85 3051 multi-standard dual LCD display DC voltage and ammeter voltmeter ammeter range DC 0-600V 0-200A blue backlight
Please noted this link only for measure DC 199.9V 10A, input 3~40V DC
D85-3051 DC digital meter can measure and display the voltage and current at he same time. Measured t voltage and current can use the common ground.
Technical Indicators
1. Accuracy: 1%±2 word
2. Displayer: LCD
3. Measure Range: DC voltage (1) 0-199.9V DC (need supply another work power between 3-40V)
(2) DC 3-19.99V, DC 3-40.0V (measured voltage can supply as work power, so the meter do not need another work power)
when let measured voltage to supply as work power, the meter measure range only from
3V to 40V, if you want the measure range start at 0V or higher than 40V, you should supply another work power between 3 - 40V.
DC current: DC 0-10A
Customers order instruments with a current measurement range within 10A (including 10A). The instrument has a built-in shunt. The customer does not need an external shunt when using it. If the customer purchases a meter with a measuring range of 10A or more, and there is no shunt inside the meter, the customer needs to purchase another shunt with the same specifications as the measuring range of the meter.
For example: if the purchased instrument has a current measurement range of 0-50A, then you must also purchase a shunt with a size of 50 / 75mV, and whether the measured current is greater than or less than 10A, you must connect the purchased shunt to use! Click on the shunts below or search for shunts in our store and add them to the shopping cart (unless the customer has a matching shunt)