8-Channel Analog Input Data Acquisition Module 4-20mA to RS485 Modbus Converter 8 Output RS485 Data Acquisition Module
Product Description
Function
8 channels of analog data to RS485 communication Convert analog sensor/meter data into digital signal Transmission to the monitoring center via RS485 Support 8 DO signal output
Specification
Performance characteristics
|
value
|
|
1
|
Provide free configuration software and local host computer software
|
|
2
|
Anti-crash hardware watchdog
|
|
3
|
5~35V power supply with anti-reverse connection, overvoltage and overcurrent protection
|
|
4
|
8 channels of analog current input 0~20mA acquisition
|
|
5
|
8 channels of analog voltage input 0~10V, 0~30V acquisition
|
|
6
|
Support analog calibration
|
|
7
|
Support 8 NPN switch output
|
|
8
|
12-bit resolution, 0.1% precision ADC
|
|
9
|
High-performance 32-bit ARM processor
|
|
10
|
Support ModbusRTU slave station protocol
|
|
11
|
12-way indicator light, with electrical protection RS485 communication interface
|
|
12
|
The temperature range of industrial machines can cope with harsh on-site environments
|
|
13
|
Custom linear analog data conversion
|
Installation Instructions
Internal integrated range switching jumper device
Support voltage/current acquisition internal switching Users can jumper wires according to their needs to switch the voltage or current acquisition mode Support adjustment range, 0~10V, 0~30V, 0~20mA switch
Internal acquisition mode, range switching technology
Support voltage 0~5V, 0~10V, 0~30V, current 0~20, 4~20ma high-precision acquisition and switching Built-in voltage and current acquisition mode switching jumper device Voltage or current acquisition switch Multiple range switching, acquisition range switching
Support 8 DO outputs
Cooperate with external relay/switch Remote control While supporting the acquisition of analog quantity, the switch linkage The user can set each channel of AI "up/lower limit" linkage operation "DO" When the AI input triggers the "upper/lower limit" value alarm, the DO output will jump immediately. It can also independently control 8 DO signal outputs and control external switches.
Support analog calibration function
When the equipment is affected by factors such as aging, temperature, etc., the accuracy of the analog quantity The user performs secondary calibration through the configuration software to improve the accuracy of the analog quantity Obtain the required accurate analog data
Terminal structure
VDC: Positive power supply Al1: Analog input terminal 1 AI5: Analog input 5 GND: negative terminal of power supply AI2: Analog input 2 AI6: Analog input 6 A+: 485 communication line A AI3: analog input terminal 3 Al7: Analog input terminal 7 B-: 485 communication line B Al4: Analog input 4 AI8: Analog input 8
Operation indicator
8 indicators on the top D1: DO1 output status indicator. On: DO has output Off: DO has no output D2: DO2 output status indicator. On: DO has output Off: DO has no output D3: DO3 output status indicator. On: DO has output Off: DO has no output D4: DO4 output status indicator. On: DO has output, DO has no output D5: DO5 output status indicator. On: DO has output Off: DO has no output D6: DO6 output status indicator. On: DO has output Off: DO has no output D7: DO7 output status indicator. On: DO has output Off: DO has no output D8: DO8 output status indicator. On: DO has output Off: DO has no output 4 indicators at the bottom ESYS: reserved GSYS: reserved PWR: Always on during normal power supply SYS: System status light, flashes once per second during normal operation