(function(){
let w = window.innerWidth;
function setHeaderCssVar() {
const headerEle = document.getElementById('shoplaza-section-header');
if(!headerEle){ return };
document.body.style.setProperty('--window-height', `${window.innerHeight}px`);
document.body.style.setProperty('--header-height', `${headerEle.clientHeight}px`);
const mdScorllHideEle = headerEle.querySelector('.header__mobile .header__scroll_hide');
if (mdScorllHideEle) {
document.body.style.setProperty('--header-scroll-hide-height-md', `${mdScorllHideEle.clientHeight}px`);
}
const pcScorllHideEle = headerEle.querySelector('.header__desktop .header__scroll_hide');
if (pcScorllHideEle) {
document.body.style.setProperty('--header-scroll-hide-height-pc', `${pcScorllHideEle.clientHeight}px`);
}
}
function handlResize() {
if(w == window.innerWidth){return};
w = window.innerWidth;
setHeaderCssVar();
};
function init(){
setHeaderCssVar();
window.removeEventListener('resize', window._theme_header_listener)
window._theme_header_listener = handlResize;
window.addEventListener('resize', window._theme_header_listener);
}
init();
})();
${data.index + 1}/6
Description
6 Points Smart LCD Flow Totalizer Flow Meter Water Temperature Quantitative Controller Meter for Filling Machine
Product Description
Flow meter
Model: YF-S403 Interface size: 6 points (G3/4) Operating voltage range: DC 5~ 18V Water pressure resistance:> 1.75MPa Output pulse high level: >DC4.5V (input voltage DC5V) Output pulse low level: 100MQ Flow range: 2-60 L/min within 3% Tightness: Close each hole, add 1.7Mpa water pressure test for 1 minute without leakage and deformation Flow pulse characteristics: (Hz) = (5*Q)+5% (horizontal test) (Q is flow rate L/min)
Solenoid valve
Model: FPDJ-08 Working voltage: DC12V/DC24V/AC220V Specification: G3/4 six points Power: 5W Take over method: water inlet G3/4 water outlet G3/4 Medium temperature: 0~ 100°C Working pressure: 0.02~0.8MPa
Specification
item
value
Operating voltage range
DC24V ±8V/1A
Operating voltage of solenoid valve
DC12V/0.3A-0.5A (normally closed solenoid valve)
Flow probe voltage
DC5V (flow probe input pulse signal)
Quantitative range
0.1-9999 liters/gallon, K value can be set in the instrument constant maximum value 1-9999 liters/minute, gallons/minute
Installation Instructions
Precautions
The decimal point is accurate to the last two digits at most. When the K value is changed and the password is changed, the other unused keys are invalid. In other interfaces, if there is no operation for 20 seconds, it will automatically exit to the system default interface or when the user presses "Start/Stop", the system will immediately activate the solenoid valve and return to the default interface.